| Z 109REG |
| |
| Description |
The Seneca Z109REG is a Universal Isolating Converter and Transmitter which is designed to accept a single channel input in either Voltage, Current or from a Thermocouple or Potentiometer; the selected input is then isolated and converted to a standard Current or Voltage output.
The DIN Rail mountable Z109REG is fully configurable using DIP Switches, alternatively the device can be configured using the free Seneca Z-SETUP-REG software (see below for more information) and a PC connected to the device using the neat PM001600 Serial cable (tick box above to purchase). |
|
|
 |
|
| Z 109PT |
| |
| Description |
The Seneca Z109PT is designed to accept a single input from a standard 2,3 or 4 wire connected PT100 probe and give a single, isolated, analogue output, easily selectable in both range and type using DIP switches.
The Z109PT with it's three-point galvanic separation between input, output and power supply can be positioned at a considerable distance up to a few hundred meters from the probe without running the risk of obtaining a measurement affected by the differences in potential or the disturbances present in the earthling circuit.
The Z109PT is DIN Rail mountable and features easy wiring using a detachable cage clamp "plug in" wire terminal. |
|
|
| |
|
|
|
|
|
|
|
|
| |
 |
|
Z 111 |
| |
| Description |
The Seneca Z111 is a Frequency to Voltage & Current converter. The Z111 is designed to receive a single channel Frequency pulsating signal input (see specifications for details) which is then isolated and converted to a standard Voltage or Current output signal.
DIN Rail mountable the Z111 as a fixed frequency range and features noise discrimination levels, Output offset , full scale Voltage, all configurable using DIP Switch.
|
|
|
 |
|
| Z 113S |
| |
| Description |
The Seneca Z109PT is designed to accept a single input from a standard 2,3 or 4 wire connected PT100 probe and give a single, isolated, analogue output, easily selectable in both range and type using DIP switches.
The Z109PT with it's three-point galvanic separation between input, output and power supply can be positioned at a considerable distance up to a few hundred meters from the probe without running the risk of obtaining a measurement affected by the differences in potential or the disturbances present in the earthling circuit.
The Z109PT is DIN Rail mountable and features easy wiring using a detachable cage clamp "plug in" wire terminal. |
|
|
| |
|
|
|
|
|
|
|
|
| |
 |
|
K120 RTD |
| |
| Description |
The Seneca K120RTD is designed to accept a single input from a standard 2,3 or 4 wire connected PT100 probe or a Ni100 probe and give a single, isolated, analogue output, ideal for use with a standard 4 to 20mA loop or voltage system. Being a K-Liner it features a super slim enclosure, just 102.5x93.1x6.2 mm and is highly configurable using it's DIP Switch. The DIN-Rail mountable K120RTD offers optional K-BUS connectivity allowing further savings in time and wiring by bussing together the nominal 24V DC power supply connections. |
|
|
 |
|
K107A |
| |
| Description |
The Seneca K107A is designed to accept a single half duplex RS-485 input and give a single, isolated, half duplex RS-485 output, effectively amplifying, boosting, existing RS-485 signals for transmission over longer distances, alternatively the K107A can be used for isolating purposes in order to avoid interferences. Being a K-Liner it features a super slim enclosure, just 102.5 x 93.1 x 6.2 mm. The DIN-Rail mountable K107A offers optional K-BUS connectivity allowing further savings in time and wiring by bussing together the nominal 24V DC power supply connections. |
|
|
| |
|
|
|
|
|
|
|
|
| |
 |
|
K109 TC |
| |
| Description |
The Seneca K109TC is designed to accept a single input from a selectable range of standard thermocouples and give a single, isolated, analogue output, easily selectable in both range and type using DIP switches. Being a K-Liner it features a super slim enclosure, just 102.5x93.1x6.2 mm. The DIN-Rail mountable K109TC offers optional K-BUS connectivity allowing further savings in time and wiring by bussing together the nominal 24V DC power supply connections |
|
|
 |
|
S109S Galvanised Signal Converters |
| |
| Description |
Power supply with galvanic separation for 0-20 mA and 4-20
mA current loops, with insulation voltage of 2000 Vac
between the input and output circuits, high linearity and
precision.
Powers both the input and output loop at a voltage of 20Vdc,
used for insulating measuring circuits between transducers
in the field and acquisition instruments in order to prevent
interferences.
A signaling LED on the front panel indicate power on.
The self-extinguishing Noryl case is the width of 2 DIN
modules and is designed to fit on 35 mm mounting rail (DIN
46277). |
|
|
| |
|
|
|
|
|
|
|
|
| |
 |
CONTROL UNIT |
| |
| Description |
PLC, Web Server, RTU
RS485 for data exchange with peripherals
RS232 interface (user free/programming
Ethernet port for supervising networks and
remot connection
32-bit RISC Microprocessor, CPU RISC 200
MHz -20 MIPS; memory: 8 MB RAM, 16 MB
flash (data)
Battery backup for retention variables |
|
|
 |
All In One Remote Control |
| |
| Description |
On-board isolated I/O (16 DI, 8 DO,
4 AI, 2 AO) with integral connectors
I/O expansion with DIN Series Z-PC modules
3 serial communication ports
+ 1 Ethernet 10 Base-T
Modem GSM/GPRS dual band
(PSTN as option) |
|
| |
|
|
|
|
 |
Multi-function control units
(PLC, Web Server, Datalogger, Bridge) |
| |
RTU
Analog & digital I/O modules
Communication modules
Software & accessories |
|
|
 |
K-Line |
| |
Resolution @ 14 bit
Precision class 0.1%
3 way isolation
Tiny dimensions (102,5 x 93,1 x 6,2 mm)
Spring-cage terminal block and/or DIN bus connection system
Power bridging terminal - DIN rail bus connector
Easy installation and maintenance
Setup via DIP Switches
Low power consumption
Digital decoupling of input signal
Protection circuit against output overcurren |
|
| |
|
|
|
|
 |
| S-LINE |
| |
 |
2, 3, 6, 8, 9 DIN modules |
 |
AC powered (115-230 V) |
 |
Up to 4,500Vac galvanic isolation |
 |
Signal converters, galvanic isolators, flow computers, industrial supplies, overvoltages protections |
|
|
 |
| MICRO RTU |
| |
 |
Remote control of isolated sites |
 |
Cathodic protection surveillance |
 |
Configuration: 4 DI, 2 AI, 2 DO (GP version),
2 DI, 2 AI (PC version), GSM Full Type Approval |
 |
Memories: 64 KB EEPROM, 2 MB flash |
 |
Temporary turn on for sms receiving / sending |
 |
Data transmission on event or on demand |
 |
IP44 external case |
 |
Tiny dimension (65 x 130 x 55 mm internal unit) |
 |
14,4 V battery power supply, 3 years life-time |
|
| |
|
|
|
|
 |
| Z-LINE |
| |
 |
Analogue and digital signal converters |
 |
Isolators |
 |
Communication Interfaces |
 |
Temperature transmitters |
 |
Splitters |
 |
Trip amplifiers |
 |
Math modules |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
|
|
| |
|
|
|
|
|
|
|
|
| |
 |
|
SENECA Calibrators TEST-3 |
| |
Precision class: 0,1%
Voltage Measure/Simulation: 0–10 V
Current Measure/Simulation: 0–20 mA
Functions setting by encoder button
High-luminosity OLED display, 128x64 points
5 languages graphic menu (Italian, English, German, French, Spanish)
Supply by Ni-Mh 2500 mA rechargeable batteries |
|
|
|
| |
|
|
|
|
|
|
|
|
|