Z 109REG
 
Description

The Seneca Z109REG is a Universal Isolating Converter and Transmitter which is designed to accept a single channel input in either Voltage, Current or from a Thermocouple or Potentiometer; the selected input is then isolated and converted to a standard Current or Voltage output.

The DIN Rail mountable Z109REG is fully configurable using DIP Switches, alternatively the device can be configured using the free Seneca Z-SETUP-REG software (see below for more information) and a PC connected to the device using the neat PM001600 Serial cable (tick box above to purchase).

   
Z 109PT
 
Description

The Seneca Z109PT is designed to accept a single input from a standard 2,3 or 4 wire connected PT100 probe and give a single, isolated, analogue output, easily selectable in both range and type using DIP switches.

The Z109PT  with it's three-point galvanic separation between input, output and power supply can be positioned at a considerable distance up to a few hundred meters from the probe without running the risk of obtaining a measurement affected by the differences in potential or the disturbances present in the earthling circuit.

The Z109PT is DIN Rail mountable and features easy wiring using a detachable cage clamp "plug in" wire terminal.

 
                 
   

Z 111

 
Description

The Seneca Z111 is a Frequency to Voltage & Current converter. The Z111 is designed to receive a single channel Frequency pulsating signal input  (see specifications for details) which is then isolated and converted to a standard Voltage or Current output signal.
DIN Rail mountable the Z111 as a fixed frequency range and features noise discrimination levels, Output offset , full scale Voltage, all configurable using DIP Switch.

 

   
Z 113S
 
Description

The Seneca Z109PT is designed to accept a single input from a standard 2,3 or 4 wire connected PT100 probe and give a single, isolated, analogue output, easily selectable in both range and type using DIP switches.

The Z109PT  with it's three-point galvanic separation between input, output and power supply can be positioned at a considerable distance up to a few hundred meters from the probe without running the risk of obtaining a measurement affected by the differences in potential or the disturbances present in the earthling circuit.

The Z109PT is DIN Rail mountable and features easy wiring using a detachable cage clamp "plug in" wire terminal.

 
                 
   

K120 RTD

 
Description

The Seneca K120RTD is designed to accept a single input from a standard 2,3 or 4 wire connected PT100 probe or a Ni100 probe and give a single, isolated, analogue output, ideal for use with a standard 4 to 20mA loop or voltage system. Being a K-Liner it features a super slim enclosure, just 102.5x93.1x6.2 mm and is highly configurable using it's DIP Switch. The DIN-Rail mountable K120RTD offers optional K-BUS connectivity allowing further savings in time and wiring by bussing together the nominal 24V DC power supply connections.  

   

K107A

 
Description

The Seneca K107A is designed to accept a single half duplex RS-485 input and give a single, isolated, half duplex RS-485 output, effectively amplifying, boosting, existing RS-485 signals for transmission over longer distances, alternatively the K107A can be used for isolating purposes in order to avoid interferences. Being a K-Liner it features a super slim enclosure, just 102.5 x 93.1 x 6.2 mm. The DIN-Rail mountable K107A offers optional K-BUS connectivity allowing further savings in time and wiring by bussing together the nominal 24V DC power supply connections. 

 
                 
   

K109 TC

 
Description

The Seneca K109TC is designed to accept a single input from a selectable range of standard thermocouples and give a single, isolated, analogue output, easily selectable in both range and type using DIP switches. Being a K-Liner it features a super slim enclosure, just 102.5x93.1x6.2 mm. The DIN-Rail mountable K109TC offers optional K-BUS connectivity allowing further savings in time and wiring by bussing together the nominal 24V DC power supply connections

   

S109S Galvanised Signal Converters

 
Description

Power supply with galvanic separation for 0-20 mA and 4-20
mA current loops, with insulation voltage of 2000 Vac between the input and output circuits, high linearity and precision.

Powers both the input and output loop at a voltage of 20Vdc,
used for insulating measuring circuits between transducers
in the field and acquisition instruments in order to prevent interferences.

A signaling LED on the front panel indicate power on. The self-extinguishing Noryl case is the width of 2 DIN modules and is designed to fit on 35 mm mounting rail (DIN 46277). 

 
                 
 

CONTROL UNIT

 
Description

PLC, Web Server, RTU
RS485 for data exchange with peripherals
RS232 interface (user free/programming
Ethernet port for supervising networks and
remot connection
32-bit RISC Microprocessor, CPU RISC 200
MHz -20 MIPS; memory: 8 MB RAM, 16 MB
flash (data)
Battery backup for retention variables

 

All In One Remote Control

 
Description

On-board isolated I/O (16 DI, 8 DO,
4 AI, 2 AO) with integral connectors
I/O expansion with DIN Series Z-PC modules
3 serial communication ports
+ 1 Ethernet 10 Base-T
Modem GSM/GPRS dual band
(PSTN as option)

 

         

Multi-function control units
(PLC, Web Server, Datalogger, Bridge)

 

RTU
Analog & digital I/O modules
Communication modules

Software & accessories

 

 

K-Line

 

Resolution @ 14 bit
Precision class 0.1%
3 way isolation
Tiny dimensions (102,5 x 93,1 x 6,2 mm)
Spring-cage terminal block and/or DIN bus connection system
Power bridging terminal - DIN rail bus connector
Easy installation and maintenance
Setup via DIP Switches
Low power consumption
Digital decoupling of input signal
Protection circuit against output overcurren

         
S-LINE
 
2, 3, 6, 8, 9 DIN modules
AC powered (115-230 V) 
Up to 4,500Vac galvanic isolation
Signal converters, galvanic isolators, flow computers, industrial supplies, overvoltages protections
 
MICRO RTU
 
Remote control of isolated sites
Cathodic protection surveillance
Configuration: 4 DI, 2 AI, 2 DO (GP version),
2 DI, 2 AI (PC version), GSM Full Type Approval
Memories: 64 KB EEPROM, 2 MB flash
Temporary turn on for sms receiving / sending
Data transmission on event or on demand
IP44 external case
Tiny dimension (65 x 130 x 55 mm internal unit)
14,4 V battery power supply, 3 years life-time

 

         
Z-LINE
 
Analogue and digital signal converters
Isolators
Communication Interfaces
Temperature transmitters
Splitters
Trip amplifiers
Math modules
   

 

 
                 
 
 
Touchscreen LCD operator panel
 
5.6” monochrome display with white LED backlight
1/4 VGA (320x240 pixel) resolution
Resistive touchscreen
Connection to industrial bus systems and Ethernet (requires optional plug-in modules)
32 MB user memory
     
 
Touchscreen LCD operator panel
 

5,6" colours display
Power supply 18..30 Vdc
16 colours display STN,
5,6" Resolution 320 x 240 pixel
16 raws x 40 columns 32 MB SSFDC memory card
Ports: RS232, RS422, RS485, Printer / PC Backup battery

 
                 
 
 

SENECA Calibrators TEST-3

 

Precision class: 0,1% 
Voltage Measure/Simulation: 0–10 V
Current Measure/Simulation: 0–20 mA
Functions setting by encoder button
High-luminosity OLED display, 128x64 points
5 languages graphic menu (Italian, English, German, French, Spanish) 
Supply by Ni-Mh 2500 mA rechargeable batteries

 
                 
 

Copyright © 2008 Status Automation Technologies Sdn.Bhd. All Rights Reserved. Web Site Designed By NetBusiness Solution